WBP series power system

WBP-400

WBP-500

WBP-750

WBP-800

WBP-1200

Rated power, KWe(1) 400
500
750
800
1,200

Gas energy input, Kcal/KWe-h(2)

2,750

2,920

2,750

No. of gensets

1

2

3

2

3

Genset gas engine

100% producer gas, 4-stroke, 1000 RPM

- Make

Shengdong

Cummins

Shengdong

- Model (aspiration(3))

JG12V190ZLDK-2

GTA1710G (TA)

JG12V190ZLDK-2

- No. of cylinders

12

12

12

- Displacement, L

71.45

28

71.45

Genset alternator

Siemens 1000 RPM, 400VAC, 50Hz

Stamford 1500 RPM,

415VAC, 50Hz

Siemens 1000 RPM,

400VAC, 50Hz

- Model

1FC6 454-6LA42-Z

HC4E

1FC6 454-6LA42-Z

- KVA

625

380

625

WBP series CHP system

WBP-400-CHP

WBP-500-CHP

WBP-750-CHP

WBP-800-CHP

WBP-1200-CHP

- Jacket heat recovery, KWth

240

520

780

480

720

- Exhaust heat recovery, KWth

400

300

450

800

1200

WBG gasifier model

WBG-600

WBG-850

2 x WBG-500

WBG-1100

WBG-1800

Bio-fuel

Wood chips, briquettes and pellets, nut shells, sunflower hulls, corn cob and similar

   -Size

Chips: 40-100 mm; Briquettes: 10-100 mm; Pellets: 8-20 mm

   -Moisture

< 20%

   -Consumption, kg/h, max.

500

640

960

1000

1500

   -Fuel charge

Batch during gasifier operation

Typical gas composition

CO = 19 ± 3%    CO2 = 10 ± 3%     N2 – 50%      H2 = 18 ± 2%     CH4 = upto 3%

Gas temperature

300 - 500°С at oulet from gasifier, < 30°С after scrubber

Gas LHV

1,150 – 1,300 KCal/Nm3 depending on bio-fuel

Ash/char removal

Dry, continuous

 
(1) In grid-connected duty;

(2) At 100% load

(3) NA – Natural aspiration, TA – Turbocharged after cooled, TI - Turbocharged inter cooled
 
For other configurations and more details, call us on +44 1462 437347 or email sales@flextechnologies.co.uk.